Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 45
Filter
1.
Rev. Ciênc. Plur ; 7(2): 61-73, maio 2021. tab
Article in Portuguese | BBO, LILACS | ID: biblio-1282737

ABSTRACT

Introdução:Os sistemas adesivos possibilitama execução de restaurações estéticas e minimamente invasivas, sendo, portanto,objeto de pesquisas para contornar os problemas que se apresentam no procedimento restaurador.Objetivo:Avaliar in vitroa resistência de união de um sistema adesivo autocondicionante, e deste modificado com soluções extrativas de semente de uva.Metodologia:Duas soluções extrativas foram preparadas comextrato de semente de uva em pó dissolvido em acetona e etanol. A partir delas e de umadesivo,seis sistemas adesivos autocondicionantes experimentais foram preparados, diferindo quanto aosolvente utilizado eàsproporções entre adesivo puro e solução extrativa(7,5%, 15% e 30%). Setenta incisivos bovinos hígidos tiveram as raízes removidas com disco de carborundum e as faces vestibulares desgastadas comlixas d'água de granulação 120, 240, 600 e 1200 sob refrigeração até expor a dentina superficial. Os dentes foram distribuídos aleatoriamenteem sete grupos distintos: Controle; A7,5; A15; A30; E7,5; E15; e E30, contendo 10 elementos cada. A aplicação dos adesivos foi executada de acordo com as recomendações do fabricante do adesivo controle. A restauração foi realizada com uma matriz de silicone com dimensões 2mm de altura e 4mm de diâmetro e inserido o material restaurador em incremento único e fotopolimerizado por 40s. Após três meses armazenados em água destilada, os espécimes foram submetidos ao teste de resistência de união. Foi empregado ométodo estatísticoTeste Paramétrico Anova 1 Fator e pós-teste de Tamhane (p<0,05). Resultados:Os grupos A7,5, E7,5 e E30 não apresentaram diferença em relação ao grupo Controle; A15 e A30 mostraram desempenho estatisticamente semelhante entre si; e E15 não apresentou diferença estatística em relação aos outros adesivos.Conclusões:A adição de proantocianidina teve efeitos diferentes,dependendodos solventes e das concentrações utilizadas, mas sem alterar significativamente o desempenho do adesivo (AU).


Introduction:Adhesive systems make it possible to perform aestheticand minimally invasive restorations, being the subject of research to circumvent the problems that arise in the restorative procedure.Objective:Evaluate in vitrothe bond strength of a self-etching adhesive system,and modified with extractive grape seed solutions. Methodology:Two extractive solutions were prepared with powdered grape seed extract dissolved in acetone and ethanol. From them and an adhesive, six experimental self-etching adhesive systems were prepared, differing in terms of the solvent used and the proportions between pure adhesive and extractive solution(7.5%, 15% and 30%). Seventy healthy bovine incisors had their roots removed with carborundum disc and the vestibular faces were worn with sandpaper with granulation water 120, 240, 600 and 1200 under refrigeration until the superficial dentin was exposed. The teeth were randomly assigned to seven different groups: Control; A7.5; A15; A30; E7.5; E15; and E30, containing 10 elements each. The application of the adhesives was carried out according to the recommendations of the manufacturer of the control adhesive. The restoration was performed with a silicone matrix with dimensions 2mm high and 4mm indiameter and the restorative material was inserted in a single increment and light cured for 40s. After three months stored in distilled water, the specimens were submitted to the bond strength test. The statistical method Parametric Test Anova 1 Factor and Tamhane post-test (p<0.05) were used. Results:Groups A7.5, E7.5 and E30 showed no difference in relation to the Control group; A15 and A30 showed a statistically similar performance; and E15 showed no statistical difference in relation to the other adhesives. Conclusions:The addition of proanthocyanidin had different effects, depending on the solvents and concentrations used, but without significantly altering the performance ofthe adhesive (AU).


Introducción: Sistemas adhesivos permiten realizar restauraciones estéticas y mínimamente invasivas, siendo objeto de investigación para sortear problemas que surgen en elprocedimiento restaurador. Objetivo: Evaluar in vitrola fuerza de unión de un sistema adhesivoautograbante y modificado con soluciones extractivas de semilla de uva. Metodología: Se prepararon dos soluciones extractivas con extracto de semilla de uva en polvo disuelto en acetona y etanol. A partir de ellos y de un adhesivo, se prepararon seis sistemas experimentales de adhesivos autograbantes, que se diferencian en cuanto al solvente utilizado y las proporciones entre adhesivo puro y solución extractiva (7,5%, 15% y 30%). Setenta incisivos bovinos sanos fueron removidos con un disco de carborundo y las caras vestibulares fueron usadas com lija de agua de granulación 120, 240, 600 y 1200 bajo refrigeración hasta que la dentina superficial quedo expuesta. Los dientes se asignaron aleatoriamente a siete grupos diferentes: Control; A7,5; A15; A30; E7,5; E15; y E30, que contiene 10 elementos cada uno. La aplicación de los adhesivos se realizó siguiendo las recomendaciones del fabricante del adhesivo de control. La restauración se realizó con matriz de silicona con 2mm de altura y 4mm de diámetro y el material restaurador se insertó en un solo incremento y se fotopolimerizó durante 40s. Tres meses después, almacenados em agua destilada, las muestras se sometieron a la prueba de resistencia de la unión. Se utilizó el método estadístico Prueba Paramétrica Factor Anova 1 y post-prueba de Tamhane (p<0,05). Resultados: Los grupos A7,5, E7,5 y E30 no mostraron diferencias em relación con el grupo Control; A15 y A30 mostraron un desempeño estadísticamente similar; y E15 no mostró diferencia estadística en relación con los otros adhesivos. Conclusiones: La adición de proantocianidina tuvo diferentes efectos, dependiendo de los disolventes y concentraciones utilizadas, pero sin alterar significativamente el rendimiento del adhesivo (AU).


Subject(s)
Animals , Cattle , Dental Polishing/instrumentation , Proanthocyanidins , Flexural Strength , Solvents , In Vitro Techniques/methods , Brazil , Analysis of Variance , Dental Cements/chemistry , Grape Seed Extract
2.
RGO (Porto Alegre) ; 68: e20200004, 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1091883

ABSTRACT

ABSTRACT Objective The aim of this study was to evaluate the in situ hardness, compressive strength and resilience of soft lining materials used in total removable prostheses in different time intervals Methods total of 48 rectangular test specimens (10 x 3 x 2 mm) were fabricated of each of the polyvinylsiloxane-based soft liner (Mucopren Soft) and acrylic resin-based material (Trusoft), which were placed on total removable prostheses bases of 12 volunteers (n = 12). The hardness (Shore A), compressive strength (in MPa) and resilience (in Kgf/cm2) were evaluated in different time intervals: 0, 7, 30 and 60 days, at three different locations of the specimens surface. Results The two-way ANOVA and Tukey test showed that the polyvinylsiloxane-based soft liner presented higher hardness values (p = 0.0113) and higher compressive strength (p=0.0252) than the acrylic resin-based material at immediate and 7 days evaluations. The polyvinylsiloxane-based soft liner presented higher resilience values than the acrylic resin-based material at all times (p = 0.0133). Hardness and compressive strength were similar for both materials at 30 and 60 days evaluations. Conclusions For both materials,there was a tendency for an increase of hardness, compressive strength and resilience over time, influenced by the composition of the tissue conditioner. The polyvinylsiloxane-based soft liner presented higher hardness, compressive strength and resilience than the acrylic resin-based material, specially considering a long-term evaluation up to 60 days.


RESUMO Objetivo O objetivo deste estudo foi avaliar in situ a dureza, resistência à compressão e resiliência de materiais para reembasamento utilizadas em próteses totais removíveis em diferentes intervalos de tempo. Métodos Um total de 48 corpos de prova retangulares (10 x 3 x 2 mm) foram confeccionados de cada uma dos reembasadores a base de polivinilsiloxano (Mucopren Soft, Kettenbach GmbH & Co) e resina acrílica (Trusoft, Bosworth), os quais foram posicionados na base de próteses totais removíveis de 12 voluntários (n = 12). A dureza (Shore A), resistência à compressão (em MPa) e resiliência (em Kgf/cm2) foram avaliadas em diferentes intervalos de tempo: 0, 7, 30 e 60 dias, em três diferentes localizações da superfície do corpo de prova. Resultados A ANOVA a dois critérios e o teste de Tukey mostraram que o reembasador a base de polivinilsiloxano apresentou maiores valores de dureza (p = 0,0113) e maior resistência à compressão (p=0,0252) do que o a base de resina acrílica nas avaliações nos tempos imediato e 7 dias. O reembasador a base de polivinilsiloxano apresentou maior resiliência que o a base de resina acrílica em todos os tempos (p = 0,0133). Dureza e resistência à compressão foram semelhantes para ambos os materiais nos tempos 30 e 60 dias de avaliação. Conclusões Para ambos os materiais, houve tendência de aumento da dureza, resistência à compressão e resiliência com o passar do tempo, influenciado pela composição dos materiais de rembasamento tecidual. O reembasador a base de polivinilsiloxano apresentou maior dureza, resistência à compressão e resiliência que o a base de resina acrílica, considerando-se especialmente o tempo de avaliação de 60 dias.

3.
Odontología (Ecuad.) ; 22(2): 45-59, 2020.
Article in Spanish | LILACS | ID: biblio-1103546

ABSTRACT

En conductos radiculares curvos, la utilización de limas que eviten desvíos y fracturas del instrumento por fatiga y que mantengan curvaturas originales son aspectos importantes en el tratamiento endodóntico. Ob-jetivo: Se evaluó la resistencia a la fatiga cíclica de cuatro sistemas reciprocantes en una canaleta dinámica que simuló tres curvaturas diferentes. Materiales y Método: Estudio in vitro; la muestra con 48 limas se dividió en cuatro grupos (n= 12/grupo): WaveOne® (WO), WaveOne® Gold (WOG), Reciproc® (R) y Reciproc® Blue (RB), cuatro limas de cada sistema se usaron en una canaleta que simuló tres angulaciones 45°, 60° y 90°; montadas en un motor X-Smart Plus®, las limas se introdujeron 23 mm en los conductos para ser activadas continuamente a 300/500 oscilaciones/minuto hasta que se produjo la fractura. Se registró tiempo y zona de fractura. Se realizó el test Kruskal Wallis con un nivel de confianza del 95% para las comparaciones. Resul-tados: RB presentó mayor resistencia a la fatiga cíclica que WO y WOG en todas las angulaciones y que R a 90° (p= <0,05). R presentó mayor resistencia que WOG a 45° y 60°, sin embargo, a 90° WOG fue superior que R y WO (p<0,05). No hubo diferencias en cuanto a la zona de fractura que aconteció en la porción apical. Conclusiones: La resistencia se reduce cuando aumenta el grado de curvatura. RB fue significativamente más resistente a la fatiga cíclica que WO y WOG en todas las angulaciones y que R a 90°. La zona de fractura se produjo en la porción apical de las limas.


In the curved canals, the use of files that avoid deviations and fractures of the instrument due to fatigue and that maintain original curvatures are important aspects in endodontic treatment. Objective: The resistance to cyclic fatigue of four reciprocating systems was evaluated in a dynamic gutter that stimulated three different curvatures. Materials and Method: In vitro study, the sample with 48 files was divided into four groups (n = 12 /group): WaveOne® (WO), WaveOne® Gold (WOG), Reciproc® (R) and Reciproc® Blue (RB), four files from each system were used in a gutter that simulated three angulations 45o , 60 o and 90 o . The files which were mounted on an X-smart Plus® were inserted 23 mm into the conduits to be continuously activated at 300/500 oscillations per minute until the fracture occurred. Time and fracture zone were recorded. The Krustal Wallis test was performed with a 95% confidence level for the comparisons. Results: RB presented greater resis-tance to cyclic fatigue than WO and WOG at 45o and 60o, however, at 90o WOG was higher than R and WO (p<0.05). There were no differences regarding the fracture zone occurred in the apical portion. Conclusions: The resistance decreases when the degree of curvature increases. RB was significantly more resistance to cyclic fatigue than WO and WOG at all angulations and R at 90o. The fracture zone occurred in the apical portion of the files.


Em canais radiculares curvos, o uso de limas que evitem desvios e fraturas do instrumento devido à fadiga e que mantêm as curvaturas originais são aspectos importantes no tratamento endodôntico. Objetivo: avaliar a resistência à fadiga cíclica de quatro sistemas reciprocantes em uma canaleta artificial que simula três curva-turas diferentes. Materiais e Método: estudo in vitro; a amostra com 48 limas foi dividida em quatro grupos (n = 12 / grupo): WaveOne® (WO), WaveOne® Gold (WOG), Reciproc® (R) e Reciproc® Blue (RB), quatro limas de cada sistema foram usadas em uma canaleta que simulo três angulações 45 °, 60 ° e 90 °; se montaram em um motor X Smart Plus®, as limas foram inseridas 23 mm nos condutos para serem ativadas continuamente a 300/350 oscilações / minuto até ocorrer uma fratura. O tempo e a zona de fratura foram registrados. O teste de Kruskal Wallis foi realizado com um nível de confiança de 95% para as comparações. Resultados: O RB apresenta maior resistência à fadiga cíclica que o WO e o WOG em todas as angulações e que R a 90 ° (p = <0,05). R apresentou maior resistência que WOG a 45 ° e 60 °, no entanto, a 90 ° WOG foi maior que R e WO (p <0,05). No existiu diferença na zona de fratura que ocorreu na porção apical. Conclusões: a resistência diminui quando o grau de curvatura aumenta. RB foi significativamente mais resistente à fadiga cíclica do que WO e WOG em todos os ângulos e R a 90 °. A zona de fratura ocorre na parte apical das limas.


Subject(s)
Dental Pulp Cavity , Endodontics , Flexural Strength , Stress, Mechanical , In Vitro Techniques
4.
ROBRAC ; 27(83): 234-238, out./dez. 2018. tab
Article in Portuguese | LILACS | ID: biblio-997246

ABSTRACT

Objetivo: Avaliar a influência de diferentes soluções de irrigação cavitária sobre a resistência de união de um cimento resinoso de dupla polimerização. Material e Método: A partir de incisivos bovinos, foram obtidos 4 grupos (n=15), divididos aleatoriamente de acordo com a solução irrigadora empregada na limpeza cavitária, sendo: G0 - soro fisiológico + condicionamento ácido; G1 ­ EDTA + condicionamento ácido; G2 - Clorexidina 2% + condicionamento ácido + clorexidina 2% e G3 - soro fisiológico + condicionamento ácido + clorexidina 2%. Foram confeccionados cilindros de cimento resinoso para cada coroa, utilizando-se uma matriz de Tygon com diâmetro interno de 1 mm e altura de 2 mm. O teste de resistência adesiva por microcisalhamento foi realizado após 3 meses de armazenamento dos espécimes em soro fisiológico a 37ºC. Os dados foram submetidos ao teste de Kruskall-Wallis, seguido do teste de Dunn (p<0,05). Resultados: Os grupos G0, G1 e G3 não apresentaram diferenças significativas entre si (p>0,05). Os menores valores foram observados no grupo G2 (p<0,05). Conclusões: As soluções irrigadoras EDTA e soro fisiológico utilizadas previamente ao condicionamento ácido da dentina não interferiram, significativamente, na resistência de união, porém, a solução de clorexidina utilizada após o condicionamento ácido influenciou negativamente nos valores de resistência de união.


Objectives: This study aimed to evaluate the influence of different cavity irrigation solutions on the bond strength of a dual-curing resin cement. Methods: From bovine incisors, 4 groups (n=15), were randomly divided according to the irrigating solution for cavity cleaning: G0 ­ saline + acid etching; G1 ­ EDTA + acid etching; G2: Chlorhexidine 2% + acid etching + Chlorhexidine 2%; and G3 ­ Saline + acid etching + Chlorhexidine 2%. Resin cement cylinders were made for each crown, using a Tygon matrix with internal diameter of 1 mm and height of 2 mm. The specimens were stored for 3 months at 37oC, and then subjected to microshear tests. Data were statistically analyzed by Kruskal-Wallis test followed by Dunn (p<0.05). Results: There were no statistically significant differences between G0, G1 and G3 groups (p>0.05). The lowest values were observed in G2 group (p<0.05). Conclusion: The irrigation solutions EDTA and saline used before to the acid etching of dentin did not interfere, significantly, in the bond strength, however, the solution of chlorhexidine used after the acid etching influenced negatively.

5.
Braz. dent. sci ; 21(3): 315-319, 2018. tab, ilus
Article in English | LILACS, BBO | ID: biblio-911407

ABSTRACT

Objective: The aim of the study was to evaluate the effect of aging through different thermocycling protocols on the flexural strength of a feldspathic ceramic. Material and Methods: Fifty ceramic bars, Vitablock Mark II (VITA), with dimensions of 18X4X2mm were prepared. The bars were randomly distributed to the groups (n = 10), which were defined according to the number of thermal cycles (TCy): G0 - no TCy; G500 - 500 cycles of TCy; G6000 - 6000 TCy; G10000 - 10000 TCy; G15000 - 15000 TCy. After aging, the specimens were subjected to the three point bending test in a universal testing machine (EMIC DL 1000), under 0.5mm/min speed and loading of 50kgf, until catastrophic failure. A sample of each group was evaluated for topographic morphology under Scanning Electron Microscopy. Results: For mechanical testing, the following mean values and standard deviation (MPa) were obtained: G0 (99.78 ± 5.07); G500 (101.64 ± 5.59); G6000 (98.13 ± 4.95); G10000 (91.77 ± 9.68); G15000 (101.51 ± 4.22). An analysis of variance by regression equation (p = 0.387) was performed, demonstrating a weak and non-significant correlation between flexural strength and number of thermal cycles. Conclusion: It can be concluded that aging in water solely by different numbers of temperature cycles did not influence on the flexural strength of a feldspathic ceramic. (AU)


Objetivo: O objetivo do estudo foi avaliar o efeito do envelhecimento por meio de diferentes protocolos de ciclos térmicos na resistência à flexão de uma cerâmica feldspática. Material e Métodos: Cinquenta barras de cerâmica, Vitablock Mark II (VITA), com dimensões de 18X4X2mm foram preparadas. As barras foram distribuídas aleatoriamente pelos grupos (n = 10), os quais foram definidos de acordo com o número de ciclos térmicos (CT): G0 ­ nenhum; G500 - 500 CT; G6000 - 6000 CT; G10000 ­ 10000 CT; G15000 - 15000 CT. Após envelhecimento, as amostras foram submetidas ao ensaio de flexão de três pontos em uma máquina de ensaios universal (EMIC DL 1000), sob a velocidade de 0,5 mm / min e célula de carga de 50kgf, até uma falha catastrófica. Uma amostra de cada grupo foi avaliada quanto à morfologia topográfica sob microscopia eletrônica de varredura. Resultados: Para os testes mecânicos, foram obtidos os seguintes valores médios e desvio padrão (MPa): G0 (99,78 ± 5,07); G500 (101,64 ± 5,59); G6000 (98,13 ± 4,95); G10000 (91,77 ± 9,68); G15000 (101,51 ± 4,22). Uma análise de variância pela equação de regressão (p = 0,387) foi realizada, o que demonstra uma correlação fraca e não significativa entre a resistência à flexão e do número de ciclos térmicos. Conclusão: Pode-se concluir que o envelhecimento somente em água por diferentes números de ciclos térmicos não influenciou na resistência à flexão de uma cerâmica feldspática (AU)


Subject(s)
Aging , Materials Science , Metal Ceramic Alloys , Microscopy, Electron, Scanning
6.
São José dos Campos; s.n; 2018. 52 p. il., tab., graf..
Thesis in Portuguese | LILACS, BBO | ID: biblio-906910

ABSTRACT

O objetivo deste trabalho foi avaliar o efeito da fadiga na microestrutura de uma cerâmica odontológica (Y-TZP) sinterizada pelo método convencional ou por energia de micro-ondas. A hipótese nula foi que a fadiga não irá gerar alterações na microestrutura deste material. Para isto, foram confeccionados, por meio de um sistema CAD/CAM, 84 discos de zircônia (VIPI block zircon) com características finais de 12 mm de diâmetro e 1,2 mm de espessura conforme a norma ISO 6872. Os espécimes foram separados em dois grupos: Grupo I ­ Sinterização convencional: ciclo estabelecido pelo fabricante (2 horas a 1530 °C) e Grupo II ­ sinterização por energia de micro-ondas (15 min a 1450 °C). Dez amostras por grupo foram submetidas ao teste monotônico (1000 KgF ­ 1mm/min) para a determinação da carga para fratura, utilizada como parâmetro para os testes de fadiga (método step-stress e fadiga dinâmica). O teste de fadiga step-stress foi realizado utilizando 4 perfis de carga, ultra-suave, suave, moderado e agressivo, até que ocorresse a fratura. A fadiga dinâmica foi realizada com o ensaio dos discos até fratura sob cinco taxas de tensão (1, 0,1, 0,01, 0,001 e 0,0001 MPa/s), e a partir disso foram calculados o coeficiente de crescimento de trincas e módulo de Weibull (confiabilidade) para cada grupo. Foram realizadas análises complementares de densidade, translucidez, microscopia eletrônica de varredura (MEV) e difratometria de Raios-X (DRX) de ambos os grupos para a caracterização dos materiais. Os resultados da fadiga step-stress não mostraram diferenças no comportamento dos espécimes de cada grupo. Na fadiga dinâmica, os métodos de fadiga também não mostraram diferenças no comportamento e tiveram coeficientes de crescimento de trinca similares. O modulo de Weibull mostrou maiores valores de confiabilidade para o grupo micro-ondas (m = 7,9) do que para o grupo de sinterização convencional (m = 6,7). Os valores de densidade também foram semelhantes para os grupos estudados, já a translucidez foi menor para o grupo micro-ondas. As imagens de MEV mostraram microestruturas similares entre grupos, apenas uma diferença no tamanho dos grãos foi observada, 0,53 µm para os grãos de microondas e 0,89 µm para os grãos dos espécimes sinterizados convencionalmente. Conclui-se que o processo de sinterização por microondas pode ser aplicado como alternativa de sinterização de zirconia ao dia-a dia laboratorial(AU)


The objective of this work was to evaluate the microstructure and fatigue behavior of a dental ceramic (Y-TZP) sintered by conventional method or by microwave energy. The null hypothesis was that the fatigue will not effect the microstructure of this material. 84 zirconia discs (VIPI block zircon) with final characteristics of 12 mm in diameter and 1.2 mm in thickness according to ISO 6872 were made using a CAD/CAM system. The specimens were divided in two groups: Group I - Conventional sintering: cycle established by the manufacturer (2 hours at 1530 °C) and Group II - sintering by microwave energy (15 min at 1450 °C). Ten samples per group were submitted to monotonic test (1000 KgF - 1mm/min) to determine the load to fracture, used as a parameter for fatigue tests (step-stress and dynamic fatigue). The step-stress fatigue test was performed using 4 load profiles, ultramild, mild, moderate and aggressive, until the fracture. The dynamic fatigue was performed by testing the disks to fracture under five constant stress rates (1, 0.1, 0.01, 0.001 and 0.0001 MPa/s), and from this the crack growth coefficient and Weibull module (reliability) were measured for each group. Additional analyzes of density, translucency, scanning electron microscopy (SEM) and X-ray diffractometry (XRD) for both groups were carried out to characterize the materials. The results of stepstress fatigue test did not show differences in the specimens behavior of each group. Dynamic fatigue also showed no differences in behavior and had similar crack growth coefficients. The Weibull modulus showed higher reliability values for the microwave group (m = 7.9) than for the conventional sintering group (m = 6.7). The density values were also similar for the studied groups, since the translucency was lower for the microwave group. SEM images showed similar microstructures between groups, only a difference in grain size was observed, 0.53 µm for microwave grains and 0.89 µm for the conventionally-sintered grains. It is concluded that the microwave sintering process can be applied as an alternative to zirconia sintering to daily laboratory work(AU)


Subject(s)
Humans , Ceramics/adverse effects , Materials Science/adverse effects , Microwaves
7.
Rev. Ciênc. Méd. Biol. (Impr.) ; 16(3): 300-304, dez 19, 2017. tab, fig
Article in Portuguese | LILACS | ID: biblio-1293096

ABSTRACT

O constante aprimoramento dos materiais odontológicos é impulsionado pelas pesquisas científicas que, por sua vez,são incentivadas pelo mercado consumidor que busca tratamentos estéticos e duráveis. Objetivo: avaliar a resistência flexuralde duas resinas compostas convencionais e uma resina composta do sistema bulkfill. Metodologia: foram utilizadas as resinas compostas: Z100TM (microhíbrida), FiltekTM Z350 XT (nanoparticulada) e a FiltekTM Bulk fill (sistema bulkfill). Foram confeccionados dez corpos de prova de cada compósito (25x2x2mm). Testes mecânicos para avaliação da resistência flexural foram realizados, os valores de força obtidos para fratura do corpo de prova foram, então, transformados em MPa. Resultados: o valor médio de resistência flexural médio encontrado para o grupo Z100TM=108,43MPa, para o grupo FiltekTM Bulk Fill=133,30MPa e para o grupo FiltekTM XT Z350=172,53MPa. Conclusões: a resina composta convencional denanoparticulaFiltekTM XT Z350 apresentou os maiores valores de resistência flexural, seguida da resina FiltekTMBulk fill. A resina Z100TM apresentou os menores valores médios de resistência flexural.


The constant improvement of dental materials is driven by scientific research which, in turn, is encouraged by the consumer market seeking aesthetic and durable treatments.Aim: to evaluate the flexural strength between two conventional composite resins and a composite resin of the bulk fill system. Methodology: composite resins were used: Z100TM (microhybrid), FiltekTM XT Z350 (nanoparticulate) and FiltekTM Bulk fill (bulk fill system). Ten specimens of each composite (25X2X2mm) were made. Mechanical tests for evaluation of flexural strength were performed, strength values obtained for fracture of the specimen were, then, transformed into MPa.Results: the mean value for the Z100TM group = 108.43MPa, for the FiltekTM Bulk Fill group = 133.30MPa and the FiltekTM XT Z350 group = 172.53MPa. Conclusions: the conventional composite resin of FiltekTM XT Z350 showed the highest values of flexural strength, followed by FiltekTM Bulk fill resin. Z100TM resin showed the lowest values of flexural strength.


Subject(s)
Composite Resins
8.
São José dos Campos; s.n; 2017. 49 p. il., tab., graf..
Thesis in Portuguese | LILACS, BBO | ID: biblio-905941

ABSTRACT

O objetivo deste trabalho foi avaliar o silicato de lítio reforçado por zircônia quanto a sua microestrutura e as mesmas propriedades mecânicas em diferentes fases de cristalização. Cento e vinte amostras de discos de silicato de lítio reforçado por zircônia foram usinados de acordo com as normas ISO 6872 (12x1,2mm) para o ensaio de flexão biaxial. Foram separados em 4 grupos de acordo com a fase de cristalização. Grupo I: 30 amostras de Celtra pré cristalizado (CNC); Grupo II: 30 amostras de Celtra cristalizado (CC); Grupo III: 30 amostras de Suprinity Não Cristalizado (SNC) e Grupo IV: 30 amostras de Suprinity Cristalizado (SC). Os corpos de prova foram submetidos ao ensaio mecânico de flexão biaxial e em seguida realizadas análises qualitativas e quantitativas. Por meio microscopia eletrônica de varredura, microscopia eletrônica com emissão de campo MEV-FEG, EDS e difração de raios X (n=4), foi realizada a caracterização completa dos materiais e análise morfológica da microestrutura para todos os grupos. Para as análises estatísticas foram utilizados o módulo Weibull (m) e resistência característica (σ0) (AU)


The objective of this work was to evaluate the lithium silicate reinforced by zirconia as to its microstructure and the same mechanical properties in different phases of crystallization. One hundred and twenty samples of zirconiareinforced lithium silicate discs were machined according to ISO 6872 (12x1,2mm) standards for the biaxial flexural test. They were separated into 4 groups according to the crystallization step. Group I: 30 samples of Pre- Crystallized Celtra (CPC); Group II: 30 samples of Crystallized Celtra (CC); Group III: 30 samples of Uncrystallized Suprinity (SNC) and Group IV: 30 samples of Crystallized Suprinity (SC). The specimens were submitted to the mechanical biaxial flexion test and qualitative and quantitative analyzes were performed. Scanning Electron Microscopy, Electron Microscopy with Field emission SEM-FEG, EDS and X-ray diffraction (n = 4) were carried out to characterize the materials and morphological analysis of the microstructure for all groups. The Weibull (m) and characteristic resistance (σ0) were used for the statistical analysis(AU)


Subject(s)
Humans , Ceramics/chemical synthesis , Materials Science/adverse effects , Materials Science/methods
9.
Rev. odontol. UNESP (Online) ; 45(5): 271-276, Sept.-Oct. 2016. tab, ilus
Article in English | LILACS, BBO | ID: lil-798171

ABSTRACT

Background: The study of the phenomenon of fatigue is essential because implant failures usually are caused by this process. Purpose: The objective of this study was to examine the fatigue resistance of straight and anatomical abutments joints that were submitted to cyclic loads. Material and method: We used 37 Morse taper implants and 37 abutments, divided into two groups (n= 16: straight abutment, n= 21 anatomical abutment). The sets were submitted to cyclic loading (5 million) using servo-hydraulic equipment. Three sets from each group were subjected to bending tests to determine the maximum load resistance, which served as the parameter for comparison of the cyclic tests. We evaluated number of cycles, load and bending moment. Result: Of the 31 abutments cyclically tested, 17 (54.8%) fractured in fewer than 5 million cycles; 8 (25.8%) of these were straight abutments, and 9 (29%) were anatomical. A total of 14 samples (45.2%) resisted the cyclic loading. According to Fisher's exact test, there was no difference between groups as the fracture. Conclusion: Despite of the straight abutments have higher average load and bending moment on the anatomical, both types of abutments showed similar performance as the fracture strength in vitro.


Contexto: O estudo do fenômeno de fadiga é essencial porque as falhas de implantes geralmente são causadas por este processo. Objetivo: O objetivo deste estudo foi analisar a resistência à fadiga de conjuntos de pilares retos e anatômicos que foram submetidos a cargas cíclicas. Material e método: Foram utilizados 37 implantes cone Morse e 37 pilares, divididos em dois grupos (n = 16: pilares retos, n = 21: pilares anatômicos). Os conjuntos foram submetidos à carga cíclica (5.000.000) usando o equipamento servo-hidráulico. Três conjuntos de cada grupo foram submetidos a testes de flexão para determinar a resistência de carga máxima, o que serviu de parâmetro para comparação dos testes cíclicos. Foram avaliados número de ciclos, carga e momento de flexão. Resultado: Dos 31 pilares ciclicamente testados, 17 (54,8%) fraturaram em menos de 5 milhões de ciclos; 8 (25,8%) destes eram pilares retos, e 9 (29%) eram anatômicos. Um total de 14 amostras (45,2%) resistiu à carga cíclica. De acordo com o teste exato de Fisher, não houve diferença entre os grupos quanto à fratura. Conclusão: Apesar dos pilares retos terem maior carga média e momento de flexão que os anatômicos, os dois tipos de pilares apresentaram desempenho semelhante quanto a resistência à fratura in vitro.


Subject(s)
In Vitro Techniques , Dental Implants , Mechanical Phenomena , Flexural Strength
10.
Odontol. clín.-cient ; 15(1): 19-24, jan.-mar. 2016.
Article in Portuguese | LILACS, BBO | ID: biblio-965426

ABSTRACT

A busca pela excelência estética e funcional nas reabilitações com próteses implantossuportadas necessita que a restauração tenha harmoniosa integração visual da coroa protética com a arcada dentária, além de ter a capacidade de suportar carga funcional. Para isso, a seleção do pilar protético é fundamental, permitindo similaridade de cor e translucidez em relação à estrutura dentária natural. Embora os pilares de titânio sejam considerados padrão ouro para a reabilitação implantossuportada, estes podem interferir negativamente na estética fnal do caso, pois, em algumas situações, é possível visualizar o metal através da margem da gengiva. A fm de solucionar esse problema, surgem os pilares de cerâmica, desempenhando um papel fundamental na capacidade de mimetizar o elemento dental natural equivalente. Nesse sentido, o objetivo deste estudo foi, através de uma revisão da literatura, discutir os principais aspectos relacionados aos pilares cerâmicos utilizados em reabilitações implantossuportadas


To achieve aesthetic and functional excellence in rehabilitation with implant prostheses, the restorations should have harmonious visual integration of the prosthetic crown with the dental arch, and have the ability to withstand functional load. For this, the selection of the abutment is essential, allowing similarity of color and translucency in relation to natural tooth structure. Although the titanium abutments are considered the gold standard for implant-supported rehabilitation, they can adversely affect the fnal aesthetics of the case because, in some situations, the metal through the gingival margin may be seen. In order to solve this problem, ceramic abutments play a key role in the ability to mimic the natural dental element. In this context, the objective of this study was, through a literature review, discuss the main aspects related to ceramic abutments used in implant-suported rehabilitation


Subject(s)
Dental Implants , Ceramics , Esthetics, Dental
11.
São José dos Campos; s.n; 2016. 50 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867730

ABSTRACT

Este estudo avaliou o crescimento subcrítico de trincas de uma cerâmica à base de dissilicato de lítio, levando em consideração dois tipos de tratamento de superfície. Blocos de dissilicato de lítio parcialmente cristalizados, foram usinados até obter um cilindro com 12 mm de diâmetro. Após este processo, os cilindros foram cortados de forma a obter discos com espessura de 1,2 mm ± 0,2 mm, segundo norma ISO 6872/2008. Em seguida, 160 discos foram divididos em 2 grupos de estudo, de acordo com o tratamento de superfície: jateamento (Jateamento com partículas de 30 µm de alumina modificadas por sílica); e Ácido (Ácido Fluorídrico 5% por 20 segundos). As superfícies tratadas dos discos de todos os grupos receberam aplicação do agente de união silano, e foram submetidos ao tratamento térmico em um forno sob a temperatura de 100ºC durante 2 min. Todos os grupos receberam uma camada de cimento resinoso Panavia F. Vinte amostras de ambos os grupos foram submetidas ao ensaio mecânico de compressão, para a determinação da resistência à flexão biaxial, e vinte e cinco amostras de cada grupo foram submetidas ao ensaio de compressão para obtenção da resistência inerte. Trinta e cinco amostras de cada grupo foram submetidas ao teste de crescimento subcrítico de trinca. Este ensaio foi realizado em cinco taxas de tensão: 10-2 , 10-1 , 100 , 101 e 102 MPa/s. Valores obtidos pelo ensaio mecânico de compressão: Jateamento (257,53 ± 21,22 MPa) e Ácido (279,44 ± 31,42 MPa). Valores obtidos pela resistência inerte: Jateamento (235,70 ± 28,63 MPa) e Ácido (343,30 ± 47,93 MPa). Os dados do coeficiente de crescimento subcrítico de trincas (n), parâmetro do CST (D), resistência característica (σc) e módulo de Weibull (m), com base no teste de crescimento lento de trincas foram: Jateamento (n=18 ± 1,7; D=205,38 ± 0,02;σc=246,72 / 236,86-256,99 MPa; m=10,46) e Ácido (n=15 ± 1,5; D=222,88 ± 0,02; σc=362,72 / 345,38-380,93 MPa; m=8,48). Pode-se concluir que o tratamento de superfície ...


This study evaluated the fatigue behavior of a lithium dissilicate ceramic regarding different surface treatments. Partially cristalized lithium dissilicate blocks (IPS e.max CAD) were shaped into cilynders (12 mm in diameter). Cylinders were sectioned into disc shaped specimens with 1.2 mm in thickness (± 0.2 mm), according to ISO 6872/2008. Half of the specimens were sandblasted with 30 µm silica particles (Rocatec soft system) and received a layer of silane + resin cement (Pavavia F). The other half of the specimens was etched with hydrofluoric acid (HF 5%, 20 s) and alsoreceived a layer of silane + resin cement (Pavavia F). Previously to resin cement application, the silane was heat treated at 100°C. The biaxial flexural strength was determined for each surface treatment (n=20), as the subcritical crack growth behavior at 5 stress levels: 10-2 , 10-1 , 100 , 101 and 102 MPa/s. The fatigue limit will be determined with the stair case approach. Values obtained for the biaxial flexural strength teste were: Sandblasting (257.53 ± 21.22 MPa) and Acid (279.44 ± 31.42 MPa). values obtained by inert strength were: Sandblasting (235,70 ± 28,63 MPa) and Acid (343,30 ± 47,93 MPa). Slow crack growth behavior parameter (n), and CST (D), characteristic strength (σc) and Weibull modulus (m) were: sandblasting (n=18 ± 1.7; D=205.38 ± 0.02; σc=246.72 / 236.86-256.99 MPa; m=10.46) and Acid (n=15 ± 1.5; D=222.88 ± 0.02; σc=362.72 / 345.38-380.93 MPa; m=8.48). It can be concluded that the surface treatment with 5% hydrofluoric acid, lithium disilicate become more susceptible to subcritical crack growth than with the sandblasting aluminum oxide coated silica


Subject(s)
Ceramics , Fatigue , Materials Science
12.
São José dos Campos; s.n; 2016. 50 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-871398

ABSTRACT

Este estudo avaliou o crescimento subcrítico de trincas de uma cerâmica à base de dissilicato de lítio, levando em consideração dois tipos de tratamento de superfície. Blocos de dissilicato de lítio parcialmente cristalizados, foram usinados até obter um cilindro com 12 mm de diâmetro. Após este processo, os cilindros foram cortados de forma a obter discos com espessura de 1,2 mm ± 0,2 mm, segundo norma ISO 6872/2008. Em seguida, 160 discos foram divididos em 2 grupos de estudo, de acordo com o tratamento de superfície: jateamento (Jateamento com partículas de 30 µm de alumina modificadas por sílica); e Ácido (Ácido Fluorídrico 5% por 20 segundos). As superfícies tratadas dos discos de todos os grupos receberam aplicação do agente de união silano, e foram submetidos ao tratamento térmico em um forno sob a temperatura de 100ºC durante 2 min. Todos os grupos receberam uma camada de cimento resinoso Panavia F. Vinte amostras de ambos os grupos foram submetidas ao ensaio mecânico de compressão, para a determinação da resistência à flexão biaxial, e vinte e cinco amostras de cada grupo foram submetidas ao ensaio de compressão para obtenção da resistência inerte. Trinta e cinco amostras de cada grupo foram submetidas ao teste de crescimento subcrítico de trinca. Este ensaio foi realizado em cinco taxas de tensão: 10-2 , 10-1 , 100 , 101 e 102 MPa/s. Valores obtidos pelo ensaio mecânico de compressão: Jateamento (257,53 ± 21,22 MPa) e Ácido (279,44 ± 31,42 MPa). Valores obtidos pela resistência inerte: Jateamento (235,70 ± 28,63 MPa) e Ácido (343,30 ± 47,93 MPa). Os dados do coeficiente de crescimento subcrítico de trincas (n), parâmetro do CST (D), resistência característica (σc) e módulo de Weibull (m), com base no teste de crescimento lento de trincas foram: Jateamento (n=18 ± 1,7; D=205,38 ± 0,02;σc=246,72 / 236,86-256,99 MPa; m=10,46) e Ácido (n=15 ± 1,5; D=222,88 ± 0,02; σc=362,72 / 345,38-380,93 MPa; m=8,48). Pode-se concluir que o tratamento de superfície...


This study evaluated the fatigue behavior of a lithium dissilicate ceramic regarding different surface treatments. Partially cristalized lithium dissilicate blocks (IPS e.max CAD) were shaped into cilynders (12 mm in diameter). Cylinders were sectioned into disc shaped specimens with 1.2 mm in thickness (± 0.2 mm), according to ISO 6872/2008. Half of the specimens were sandblasted with 30 µm silica particles (Rocatec soft system) and received a layer of silane + resin cement (Pavavia F). The other half of the specimens was etched with hydrofluoric acid (HF 5%, 20 s) and alsoreceived a layer of silane + resin cement (Pavavia F). Previously to resin cement application, the silane was heat treated at 100°C. The biaxial flexural strength was determined for each surface treatment (n=20), as the subcritical crack growth behavior at 5 stress levels: 10-2 , 10-1 , 100 , 101 and 102 MPa/s. The fatigue limit will be determined with the stair case approach. Values obtained for the biaxial flexural strength teste were: Sandblasting (257.53 ± 21.22 MPa) and Acid (279.44 ± 31.42 MPa). values obtained by inert strength were: Sandblasting (235,70 ± 28,63 MPa) and Acid (343,30 ± 47,93 MPa). Slow crack growth behavior parameter (n), and CST (D), characteristic strength (σc) and Weibull modulus (m) were: sandblasting (n=18 ± 1.7; D=205.38 ± 0.02; σc=246.72 / 236.86-256.99 MPa; m=10.46) and Acid (n=15 ± 1.5; D=222.88 ± 0.02; σc=362.72 / 345.38-380.93 MPa; m=8.48). It can be concluded that the surface treatment with 5% hydrofluoric acid, lithium disilicate become more susceptible to subcritical crack growth than with the sandblasting aluminum oxide coated silica.


Subject(s)
Ceramics , Fatigue , Materials Science
13.
Rev. odontol. UNESP (Online) ; 44(2): 67-73, Mar-Apr/2015. tab, ilus
Article in Portuguese | LILACS | ID: lil-746236

ABSTRACT

Objetivo: Analisar a resistência à fratura por fadiga dos conjuntos implante-pilar, nos tipos reto e angulado, submetidos a cargas cíclicas similares às mastigatórias. Material e método: Foram utilizados 32 implantes (3,75 × 11 mm) com sistema cone Morse e 32 pilares, separados em dois grupos: pilares retos e angulados (n=16) (Neodent, Curitiba, PR, Brasil). Os conjuntos foram submetidos a testes cíclicos em equipamento servo-hidráulico, fixando-se o número de ciclos em cinco milhões. Foram avaliados: número de ciclos, carga e momento de força das amostras. O Teste de Fisher e o Teste ANOVA foram aplicados (p<0,005). Amostras fraturadas foram analisadas em microscopia eletrônica de varredura (MEV). Resultado: Dos pilares retos, quatro resistiram ao número de ciclos estabelecidos, suportando cargas entre 470 N e 510 N. No grupo dos angulados, nove amostras resistiram a cargas entre 570 N e 890 N. Quanto às amostras fraturadas abaixo do número de ciclos, no grupo pilar reto, nove fraturaram com cargas entre 470 N e 630 N. No grupo pilar angulado, cinco amostras fraturaram com cargas entre 760 N e 890 N. Foi calculado, para cada conjunto implante-pilar, o momento de força (Médias: Grupo reto - 4.335,2 Nmm, Grupo angulado - 3.923,3 Nmm). Conclusão: Os dois tipos de pilares (retos e angulados), em condições in vitro, comportaram-se estatisticamente de forma semelhante, sendo aceita a hipótese nula de que não há diferença de resistência à fratura entre os grupos.


Objective: The aim of this study was to verify the fatigue fracture resistance of the implant-abutment joint, in straight and angled types, subject to cyclic loads similar to chewing. Material and method: It was used 32 implants system (3.75 × 11mm) with Morse taper and 32 abutment, divided in two groups: abutment straight and angled (n = 16) (Neodent, Curitiba, PR, Brazil). The sets were submitted to cyclic testing using servo-hydraulic equipment, fixing the number of cycles at 5 million. It was evaluated the number of cycles, load and moment force of the samples. The Fisher test and ANOVA were applied (p<0,005). Fractured samples were analyzed in the scanning electron microscopy (SEM). Result: Straight abutment, four resisted the cycles number established, supporting loads between 470N and 510N. Angled abutment: nine resisted to loads between 570N and 890N. Regarding the fractured samples below the number of cycles, in the straight abutment, nine fractured with loads between 470N and 630N. In the angled abutment, five fractured with loads ranging from 760N and 890N. The moment of the force was calculated for each joint implant-abutment (Averages: Straight Group - 4335,23Nmm, angled Group - 3923,37Nmm). Conclusion: Two types of abutments (straight and angled), in vitro conditions, statistically behaved similarly, and accepts the null hypothesis that there is no difference in fracture resistance between groups. .


Subject(s)
Microscopy, Electron, Scanning , Analysis of Variance , Dental Implantation, Endosseous , Mechanical Phenomena , Flexural Strength , Titanium , In Vitro Techniques , Mouth Rehabilitation
14.
São Paulo; s.n; 2015. 90 p. ilus, tab, graf. (BR).
Thesis in Portuguese | LILACS, BBO | ID: lil-763788

ABSTRACT

A resistência de união (RU) dos materiais deve ser avaliada após a degradação da interface adesiva, tentando simular um processo que ocorre naturalmente ao longo do tempo na cavidade bucal. O presente estudo avaliou a degradação da interface adesiva em diferentes materiais utilizando o modelo de envelhecimento in vitro e in situ em dentina hígida e cariada. Noventa segundos molares decíduos hígidos e sem defeitos de esmalte, foram aleatoriamente divididos em dois grupos de acordo com o substrato a ser testado (hígido e com lesão de cárie induzida). A seguir, cada um dos grupos foi subdividido aleatoriamente de acordo com o material restaurador (n=15): resina composta associada ao sistema adesivo - RC, cimento de ionômero de vidro modificado por resina - CIVMR e cimento de ionômero de vidro de alta viscosidade - CIVAV. A superfície da dentina foi preparada e com o auxílio de cânulas de polietileno, foram confeccionados os espécimes com os materiais restauradores. Partes de um mesmo dente foram submetidas a cada envelhecimento: in vitro (24 horas e 6 meses) - armazenados em água destilada à 37°C; e in situ (uso de dispositivo intraoral palatino por voluntários em uma fase experimental de 7 dias). Os espécimes foram submetidos ao teste de microcisalhamento (MPa) para avaliação da RU, seguido de análise do padrão de fratura em estereomicroscópio (400X). Os dados foram submetidos a análise de variância de medidas repetidas seguida pelo teste de Bonferroni (? = 5%). De forma geral, o armazenamento por seis meses em água degradou o grupo CIVMR em dentina hígida (<0,001) e RC em dentina cariada (p=0,007), para os outros materiais não houve diferença estatística (p=1,00)...


Materials bond strength (BS) should be evaluated after degradation of the adhesive interface, simulating the intra-oral enviroment. This study assessed the degradation of the bonding interface of differents materials using in vitro and in situ models of aging in sound and caries - affected primary dentin. Ninety sound second primary molars without enamel defects were randomly assigned into two groups (sound and induced carious) according to the substrate to be tested. Then each group was subdivided according to the restorative material (n=15): composite resin associated with the adhesive system - CR, resin-modified glass ionomer cement - RMGIC or high-viscous glass ionomer cement- HVGIC. Dentin surface was prepared and with the aid of polyethylene tubes specimens of each restorative materials were prepared. Parts of a same tooth were subjected to in vitro and in situ models of aging. For in vitro model, the specimens were stored in distilled water at 37°C during 24 hours per 6 months; and for in situ model an intraoral palatal device was confectioned and used by volunteers in an experimental phase for 7 days.Specimens were submitted to microshear test (MPa) for BS evaluation and then stereomicroscopy (400X) analys of failure mode. Data were analyzed by repeated measures ANOVA for followed by Bonferroni test (? = 5%). In general, the storage for six months in distilled water degraded the RMGIC group in sound dentin (<0.001) and RC group in caries-affect dentin substrate (p = 0.007), for the others materials there was no statistical difference (p = 1.00)...


Subject(s)
Dentin-Bonding Agents/pharmacology , Dentin-Bonding Agents/therapeutic use , Tooth, Deciduous/physiology , Glass Ionomer Cements , Pediatric Dentistry
15.
Rev. Salusvita (Online) ; 33(3)2014. ilus
Article in Portuguese | LILACS | ID: lil-737188

ABSTRACT

Existe uma grande demanda por tratamento ortodôntico em pacientes adultos, que requerem frequentemente uma adequada adesão de bráquetes a vários substratos, além do esmalte dental, tais como: porcelanas, ligas metálicas, amálgama, ouro, dentina, resinas compostas e acrílicas. Objetivo: Apresentar revisão da literatura sobre os mecanismos adesivos empregados para a adesão de bráquetes cerâmicos aos diversos substratos encontrados na clínica odontológica e as propriedades dos bráquetes cerâmicos, sugerindo protocolos adesivos com base em evidências. Métodos: A pesquisa foi realizada na base de dados PubMed, em artigos publicados a partir de 1986, incluindo aos temas: bráquetes cerâmicos e resistência de união em ortodontia. Resultados: A estética e a biocompatibilidade foram reportadas como as maiores vantagens dos bráquetes cerâmicos. As principais limitações foram a necessidade de utilização de um agente de união (ex. silano) para a adesão química aos adesivos resinosos, a elevada resistência friccional oferecida aos arcos metálicos (prejudicando a mecânica de deslizamento) e o desgaste dentário em caso de contato entre bráquete e dente (antagonista). Conclusão: A adesão (resistência de união, em MPa) dos bráquetes deve ser sufi-cientemente elevada para resistir à descolagem espontânea, suportar os esforços mastigatórios e cargas parafuncionais eventuais, além de absorver os estresses exercidos pelo arco ortodôntico no controle tridimensional do dente. Ao mesmo tempo, deve ser suficientemente baixa para evitar a transmissão de estresse elevado ao substrato, na remoção do bráquete ao final do tratamento...


There is a high demand for orthodontic treatment in adult patients, who often require a proper adhesion of brackets to various substrates in addition to enamel, such as: porcelain, metal alloys, amalgam, gold, dentin, composite resins and acrylic. Objective: To present a comprehensive literature review on the bonding mechanisms used to bond ceramic brackets to various substrates found in the dental clinic and the properties of ceramic brackets, suggesting bonding protocols grounded on Evidence-based dentistry. Methods: The search was done in the PubMed database considering published papers from 1986 on ceramic brackets and bond strength in orthodontics. Results: Biocompatibility and esthetics were reported as the major advantages of ceramic brackets. The main limitations were the need to use a bonding agent (e.g. silane) for chemical bond to the resin-based adhesives, the high frictional resistance offered by the metal arches (impairing the sliding mechanics) and the opposing tooth wear in case of contact between bracket and tooth. Conclusion: Brackets adhesion (bond strength, in MPa) should be high enough to resist spontaneous debonding, to withstand the masticatory forces and any parafunctional loads, in addition to absorbing the stresses generated by the orthodontic arch in the three-dimensional control of the tooth. At the same time, it should be low enough to avoid the transmission of high stresses to the substrate on debonding the bracket at the end of treatment...


Subject(s)
Orthodontic Brackets/trends , Orthodontics/trends , Materials Science/adverse effects
16.
Bauru; s.n; 2014. 117 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: lil-719066

ABSTRACT

Cerâmicas a base de zircônia para coroas e próteses fixas monolíticas prometem suprimir a vulnerabilidade ao lascamento de restaurações de múltiplas camadas, proporcionando estética e resistência mecânica simultâneas. No entanto, é possível que as alterações realizadas para maximizar suas propriedades óticas possam afetar a resistência mecânica. O presente estudo teve por objetivo comparar, com base na microestrutura, o comportamento mecânico de duas marcas comerciais de zircônias monolíticas a uma zircônia convencional para infraestruturas, observando ao mesmo tempo algumas variações nos parâmetros de sinterização. As zircônias monolíticas ceramill Zolid e Prettau e a zircônia convencional IPS e.max ZirCAD foram sinterizadas sob a temperatura preconizada pelos respectivos fabricantes, formando os grupos Z1450, P1600 e I1530. Adicionalmente, foram criados os grupos Z1530 e Z1600, representados pela zircônia ceramill Zolid submetida a ciclos modificados. Foram confeccionados 13 corpos de prova para cada grupo, os quais foram submetidos aos ensaios de difração de raios-x, densidade, análise do tamanho médio de grão e resistência à flexão em 4 pontos. Os espectros de difração revelaram a presença da fase tetragonal metaestável em todos os grupos antes e após a sinterização. Quanto à densidade, apresentou-se superior a 99% apenas nos grupos formados pelas zircônias Prettau e IPS e.max ZirCAD. O tamanho médio dos grãos permaneceu abaixo de 1m em todas as situações, sendo maior para o grupo P1600 (0,814m) e menor para o grupo Z1450 (0,463m). Embora tenha sido observada uma tendência de melhoria nos resultados sob taxa de aquecimento mais lenta, os grupos formados pela zircônia monolíticas ceramill Zolid obtiveram os valores mais baixos de confiabilidade (m=4,58 para Z1530) e de resistência mecânica (621,01±138,08MPa para Z1450). A zircônia Prettau apresentou valores de resistência mecânica mais altos e homogêneos (864,18±118,21MPa), contudo inferiores aos da...


Monolithic zirconia ceramics for crown and bridge applications were designed to eliminate chipping trends of bilayered restorations, providing both aesthetic and mechanical strength. Nonetheless, it has been suggested that improvements in optical properties may affect the mechanical strength of these materials. The present study aimed to compare, based on a microstructural analysis, the mechanical behavior of two commercial monolithic zirconia ceramics with a conventional core zirconia material, as well as to verify sintering parameters modifications. Two monolithic zirconia ceramics (Ceramill Zolid and Prettau) and a conventional core zirconia material (IPS e.max ZirCAD) were sintered according to manufacturer´s recommendations, forming groups Z1450, P1600 and I1530. Extra groups, Z1530 and Z1600, were originated from ceramill Zolid zirconia specimens subjected to modified sintering cycles. The thirteen specimens that were manufactured for each group were submitted to x-ray diffraction analysis, density, average grain size determination and 4-point-bending tests. X-ray diffraction analysis revealed the presence of tetragonal metastable phase in all groups before and after sintering. Relative density found for Prettau and IPS e.max ZirCAD were greater than 99%. The average grain size remained below 1m for all groups. P1600 showed the largest grain sizes (0,814m) while Z1450 (0,463m) demonstrated the smallest ones. Groups originated from ceramill Zolid also presented the lowest Weibull modulus (m=4,58 for Z1530) and flexural strength results (621,01±138,08MPa for Z1450), regardless of non significant improvements that were achieved when using a low heating rate protocol. Prettau zirconia showed better mechanical behaviour and a more homogeneous distribution of results (864,18±118,21MPa), although lower than those of IPS e.max ZirCAD zirconia (1057,41±150,54MPa). Findings from this study show that the two commercial monolithic zircônia...


Subject(s)
Ceramics/chemistry , Zirconium/chemistry , Analysis of Variance , Hot Temperature , Materials Testing , Particle Size , Reference Values , Reproducibility of Results , Surface Properties , Tensile Strength
17.
Araraquara; s.n; 2014. 115 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867864

ABSTRACT

A retenção mecânica e a longevidade das restaurações indiretas com infraestrutura de zircônia podem ser favorecidas pela cimentação adesiva. No entanto, como a zircônia é uma cerâmica cristalina, tratamentos de superfície alternativos aos convencionais (ácido fluorídrico e silanização) devem ser utilizados com o objetivo de estabelecer união mecânica e química na interface cimento resinoso/restauração. Dentre os tratamentos promotores de retenção micromecânica, o jateamento é ainda um dos métodos mais eficazes e fáceis. Esse procedimento pode ser realizado com partículas de óxido de alumínio/alumina (Al2O3) convencionais e/ou revestidas por sílica de diferentes tamanhos e, portanto, diferentes comportamentos quanto à rugosidade e à área de superfície disponível para adesão, bem como ao molhamento por agentes de união, podem ser observados. Apesar do seu papel benéfico na resistência de união da interface cimento resinoso/zircônia e até mesmo na resistência mecânica imediata da zircônia, sabe-se que o jateamento favorece a criação de microtrincas superficiais, as quais, em longo prazo, sob as condições adversas da cavidade oral, tendem a se propagar pelo corpo do material, reduzindo sua resistência mecânica ou até mesmo promovendo sua falha catastrófica. Considerando que o protocolo convencional preconiza o jateamento da zircônia sinterizada, uma alternativa seria realizá-lo na zircônia previamente à sua sinterização, uma vez que ela seria mais propícia à criação de retenções micromecânicas e, possivelmente, os efeitos da severidade do jateamento e seus danos na resistência mecânica do material, em longo prazo, seriam minimizados. Levando-se em consideração os aspectos ressaltados, este estudo teve como objetivos: 1) Avaliar o efeito da partícula empregada no jateamento na rugosidade de superfície, molhamento e padrão morfológico de uma zircônia parcialmente estabilizada por ítria, bem como verificar a existência de correlação entre as variáveis dependentes rugosidade e molhamento; 2) Avaliar o efeito do momento do jateamento na caracterização de superfície (rugosidade, morfologia e transformação de fase) e resistência à flexão de uma zircônia parcialmente estabilizada por ítria, sua resistência de união ao cisalhamento com um cimento resinoso e o modo de fratura predominante na área adesiva. Também verificou-se a existência de correlação entre as variáveis dependentes rugosidade e resistência de união. No primeiro estudo, espécimes (14 × 14 × 1,4 mm) da zircônia Lava (3M ESPE AG) foram obtidos e, com exceção do grupo controle (n=20), jateados com uma das seguintes partículas (n=20): 1) Al2O3 de 50 µm; 2) Al2O3 de 120 µm; 3) Al2O3 de 250 µm; 4) Al2O3 de 30 µm revestida por sílica (Rocatec Soft); 5) Al2O3 de 110 µm revestida por sílica (Rocatec Plus); 6) Al2O3 de 120 µm e Rocatec Plus. As análises de rugosidade (Ra) e molhamento (pelo silano RelyX Ceramic Primer) foram realizadas nos mesmos espécimes. Para a análise da morfologia de superfície por microscopia eletrônica de varredura (MEV), foram preparados dois espécimes adicionais (6,0 × 6,0 × 1,0 mm) para cada grupo. Os dados de Ra (µm) foram analisados por ANOVA a 1 critério e teste Dunnett C (α=0,05), e os dados de molhamento por ANOVA a 1 critério (α=0,05). O teste de correlação de Spearman foi aplicado para verificar uma possível correlação entre rugosidade e molhamento. Com exceção dos grupos jateados com Al2O3 de 120 µm, os demais apresentaram valores de rugosidade estatisticamente diferentes. Com relação ao molhamento, não houve diferença estatística entre os grupos. Não foi observada correlação (rs=-0,09, P=0,27) entre rugosidade e molhamento. A partícula influenciou a morfologia de superfície da zircônia. O aumento da rugosidade pareceu acompanhar o aumento do tamanho das partículas. A análise de MEV mostrou que diferentes partículas promoveram diferenças nos padrões morfológicos. No segundo estudo, espécimes da zircônia Lava foram jateados com Al2O3 de 50 µm depois (DS); antes (AS); ou antes e depois (ADS) da sinterização da zircônia. Para a rugosidade (Ra), trinta espécimes (10 × 10 × 3,0 mm) (n=10) foram analisados em rugosímetro. Discos de resina composta (n=30) foram cimentados com RelyX ARC (3M ESPE) sobre estes espécimes e armazenados em água destilada a 37 ºC por 24 horas previamente ao ensaio de resistência de união ao cisalhamento (RC). O modo de fratura foi avaliado em estereomicroscópio (×20). A morfologia de superfície (n=2) foi avaliada por MEV (×500). Para o ensaio de resistência à flexão (RF) 4 pontos (EMIC DL2000), trinta e nove espécimes em formato de barra (20 × 4,0 × 1,2 mm) (n=13) foram jateados de acordo com os três momentos propostos, e um grupo adicional (não jateado) foi avaliado (n=13). A transformação de fase (n=1) foi analisada pelo refinamento de Rietveld com os dados da difração de raios X. Os dados de Ra (µm) e RC (MPa) foram analisados por ANOVA a 1 critério e teste de Tukey (α=0,05). O teste de correlação de Pearson determinou se havia correlação entre rugosidade e RC. Para os dados de RF (MPa), foram utilizados ANOVA a 1 critério e teste Dunnett C (α=0,05). O momento do jateamento foi significante (P<0,001) para os dados de Ra, RC e RF. Os grupos AS e DS apresentaram a maior (1,3 µm) e menor (0,7 µm) Ra. A maior RC (7,0 MPa) foi observada no grupo DAS, seguido pelo grupo DS (5,4 MPa) e, finalmente, pelo grupo AS (2,6 MPa). Todos os grupos apresentaram 100% de falha adesiva. Uma fraca correlação (r=-0,45, P<0,05) foi encontrada entre rugosidade e RC. A morfologia de superfície foi influenciada pelo momento do jateamento. Os grupos não jateado (926,8 MPa) e AS (816,3 MPa) apresentaram valores de RF estatisticamente semelhantes, porém valores menores que os grupos DS (1249,1 MPa) e DAS (1181,4 MPa), sem diferença estatisticamente significante entre eles. Os grupos não jateado, DS, AS e DAS mostraram, respectivamente, percentuais em massa de fase monoclínica de 0,0%, 12,2%, 0,0% e 8,6%. A superfície muito rugosa promovida pelo jateamento antes da sinterização da zircônia prejudicou a união com o cimento resinoso. Os padrões morfológicos após os diferentes momentos do jateamento foram condizentes com a rugosidade de superfície. Considerando a RC e a RF imediatas, o grupo DAS exibiu o melhor desempenho. O jateamento, independentemente do momento, promove transformação de fase tetragonal para monoclínica, enquanto a sinterização tende a zerar o conteúdo de fase monoclínica


The mechanical retention and longevity of indirect restorations with zirconia framework can be favored by the adhesive cementation. However, as zirconia is a crystalline ceramic, alternative surface treatments to the conventional ones (hydrofluoric acid and silanization) should be used with the aim of establishing mechanical and chemical bonding at the resin cement/restoration interface. Among the treatments that promote micromechanical retention, the air-abrasion is still one of the most effective and easy-to-use methods. This procedure can be performed with conventional and/or silica-coated aluminum oxide/alumina (Al2O3) particles of different sizes and, therefore, different behaviors regards roughness and available surface area for bonding, and also wettability by bonding agents, may be observed. Despite its beneficial role on the bond strength of the resin cement/zirconia interface and even on the short-term mechanical strength of zirconia, it is known that the air-abrasion favors the creation of surface microcracks, which, in the long term, under the adverse conditions of the oral cavity, tend to propagate towards the bulk of the material, decreasing its mechanical strength or even promoting its catastrophic failure. Whereas the conventional protocol recommends the air-abrasion of the sintered zirconia, one alternative would be to perform it on the zirconia before sintering, since it would be more favorable for the formation of micromechanical retentions and, possibly, the effects of the severity of the air-abrasion and its damage on the mechanical strength of the material, in the long term, would be minimized. Taking into account the highlighted aspects, the objectives of this study was: 1) To evaluate the effect of the particle used for air-abrasion on the surface roughness, wettability and morphological pattern of an yttria partially stabilized tetragonal zirconia, as well as to verify the correlation between the dependent variables roughness and wettability; 2) To evaluate the effect of air-abrasion moment on the yttria partially stabilized tetragonal zirconia surface characterization (roughness, morphology and phase transformation) and flexural strength, its shear bond strength to a resin cement and the predominant failure mode in the adhesive area. The correlation between the dependent variables roughness and bond strength was also verified. In the first study, specimens (14 × 14 × 1.4 mm) were obtained from Lava (3M ESPE AG) and, except for the control group (n=20), air-abraded with one of the following particles (n=20): 1) 50 µm Al2O3; 2) 120 µm Al2O3; 3) 250 µm Al2O3; 4) 30 µm silica-coated Al2O3 (Rocatec Soft); 5) 110 µm silica-coated Al2O3 (Rocatec Plus); 6) 120 µm Al2O3 and Rocatec Plus. The roughness (Ra) and wettability (by the silane RelyX Ceramic Primer) analyses were performed on the same specimens. For the surface morphology analysis by scanning electron microscopy (SEM), two additional specimens (6.0 × 6.0 × 1.0 mm) per group were prepared. The Ra (µm) data were analyzed by one-way ANOVA and Dunnett C test (α=0.05), and the wettability data by oneway ANOVA (α=0.05). Spearman correlation analysis was applied to test for a possible correlation between roughness and wettability. With the exception of the groups abraded with 120 µm Al2O3, the other ones presented statistically different roughness values. Concerning wettability, there was no significant difference among the groups. No correlation (rs=-0.09, P=0.27) was found between roughness and wettability. The particle influenced the surface morphology of the zirconia. The roughness increase seemed to have followed the size enlargement of the particles. The SEM analysis indicated that different particles provided differences in the morphological patterns. In the second study, specimens from Lava zirconia were air-abraded with 50 µm Al2O3 particles after (AS); before (BS); or before and after (BAS) zirconia sintering. For roughness (Ra), thirty specimens (10 × 10 × 3.0 mm) (n=10) were analyzed by a profilometer. Composite resin discs (n=30) were bonded with RelyX ARC (3M ESPE) on these specimens and stored in distilled water at 37 ºC for 24 h before the shear bond strength (SBS) test. Failure mode was determined with a stereomicroscope (×20). The surface morphology (n=2) was evaluated by SEM (×500). For the 4-point flexural strength (FS) test (EMIC DL2000), thirty-nine bar-shaped specimens (20 × 4.0 × 1.2 mm) (n=13) were air-abraded according to the three moments proposed, and an additional group (non-abraded) was evaluated (n=13). The phase transformation (n=1) was analyzed by Rietveld refinement with X-ray diffraction data. The Ra (µm) and SBS (MPa) data were analyzed by one-way ANOVA and Tukey's test (α=0.05). Pearson correlation analysis determined if there was correlation between roughness and SBS. For FS (MPa) data, one-way ANOVA and Dunnett C test (α=0.05) were used. Air-abrasion moment was significant (P<0.001) for Ra, SBS and FS data. The BS and AS groups presented the highest (1.3 µm) and the lowest (0.7 µm) Ra. The highest SBS (7.0 MPa) was observed for the BAS group, followed by the AS group (5.4 MPa) and, finally, by the BS group (2.6 MPa). All groups presented 100% adhesive failure. A weak correlation (r=-0.45, P<0.05) was found between roughness and SBS. The surface morphology was influenced by the air-abrasion moment. The non-abraded (926.8 MPa) and BS (816.3 MPa) groups exhibited statistically similar FS values, but lower values than the AS (1249.1 MPa) and BAS (1181.4 MPa) groups, with no significant difference between them. The non-abraded, AS, BS, and BAS groups exhibited, respectively, percentages in weight of monoclinic phase of 0.0%, 12.2%, 0.0%, and 8.6%. The very rough surface provided by the air-abrasion before zirconia sintering impaired the bonding with the resin cement. The morphological patterns after the different air-abrasion moments were consistent with the surface roughness. Considering the short-term SBS and FS, the BAS group exhibited the best performance. Air-abrasion, regardless of its performance moment, provides tetragonal to monoclinic transformation, while sintering tends to zero the monoclinic phase content.


Subject(s)
Zirconium , Microscopy, Electron, Scanning , Air Abrasion, Dental , Ceramics , Surface Properties , Shear Strength , Materials Science , Analysis of Variance , Statistics, Nonparametric
18.
São José dos Campos; s.n; 2014. 124 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867572

ABSTRACT

Foi proposto avaliar a carga de fratura de restauração cerâmica à base de dissilicato de lítio (IPS e.max CAD) submetida a diferentes protocolos de cimentação. Foram confeccionadas 70 bases de um material resinoso análogo à dentina (NEMA grade G10) simulando de maneira padronizada dentes preparados para coroa total (término em chanfro com paredes de 6 graus de convergência) e a anatomia da raiz. A porção radicular foi coberta com poliéter e incluída em poliuretano. Setenta coroas cerâmicas foram fabricadas pelo sistema CAD/CAM. Depois de avaliar a espessura do filme de cimento (técnica do cimento análogo) as coroas foram limpas em ultra-som com água destilada (5 min). Posteriormente, as coroas foram submetidas a diferentes protocolos de cimentação: FZ-cimento de fosfato de zinco; IVMR-cimento de ionômero de vidro modificado por resina; RDCS-ácido fluorídrico 5 % (20 s) + silano (1 min) + cimento resinoso dual; RDCST-ácido fluorídrico 5% (20 s) + silano (1 min) + tratamento térmico forno 100 °C (2 min) + cimento resinoso dual; RDS-silano (1 min) + cimento resinoso dual; RDST-silano (1 min) + tratamento térmico forno 100 °C (2 min) + cimento resinoso dual; RAACS-ácido fluorídrico 5% (20 s) + silano (1 min) + cimento resinoso auto-adesivo. Todas as amostras foram submetidas à ciclagem termomecânica (2.000.000 ciclos – 100 N, 4 Hz, 5 ºC – 55 ºC, tempo de permanência 60 s), com um pistão de aço inoxidável (Ø=4mm) no centro da superfície oclusal. O teste da carga de fratura foi realizado em uma máquina de ensaios universal (v = 1 mm/min à 37 °C em água destilada). Os dados de carga de fratura (N) foram submetidos aos testes ANOVA (um fator) e Tukey, com α = 0,05. Realizou-se a análise de elementos finitos para verificação da distribuição das tensões na coroa. Por meio do microscópio eletrônico de varredura foram realizadas, em duas amostras de cada grupo, fotomicrografias representativas do tratamento de superfície. Para análise fractográfica, utilizou-se ...


It was proposed to evaluate the load of fracture of a ceramic restoration-based lithium disilicate (IPS e.max CAD) submitted to different protocols cementation. 70 bases were made of a resin material similar to dentin (NEMA grade G10) to provide standardized preparations, machined to simulate a tooth prepared for full crown (ending Bevel with walls of 6 degrees of convergence) and the anatomy of the root. The root portion was covered with polyurethane poliétere included. Seventy ceramic crowns were fabricated by CAD / CAM system. After evaluating the film thickness of cement (cement analogue technique) crowns were cleaned with distilled water in ultra-som (5 min). Subsequently, the crowns were subjected to different protocols cementation: FZ-zinc phosphate cement; IVMR-ionomer resin modified glass; RDCS-hydrofluoric acid 5% (20 s) + silane (1 min) + dual resin cement , RDCST-hydrofluoric acid 5% (20 s) + silane (1 min) + heat treatment furnace 100 °C (2 min) + dual resin cement; RDS-silane (1min) + dual resin cement; RDST silane (1 min) + heat treatment furnace 100 °C (2 min) + dual resin cement; RAACS-hydrofluoric acid 5% (20 s) + silane (1 min) + self-adhesive resin cement. All samples were subjected to thermomechanical cycling (2,000,000 cycles - 100N, 4 Hz, 5 ºC - 55 ºC, dwell time 60 s), with a stainless steel piston (Ø = 4 mm) in the center of the occlusal surface. The fracture toughness test was performed in a universal testing machine (v = 1 mm/min at 37 ° C in distilled water). Data fracture resistance (N) were subjected to ANOVA (one factor) and Tukey's test with α = 0.05. We conducted a finite element analysis to check the distribution of the stresses on the crown. Through scanning electron microscopy were performed on two samples from each group, representative photomicrographs of surface treatment . For fractographic analysis, we used the stereo type of fracture classification and correlation between fracture load and the number of fragments . ...


Subject(s)
Humans , Ceramics , Crowns , Hydrofluoric Acid , Materials Science
19.
Araraquara; s.n; 2014. 68 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867828

ABSTRACT

O propósito do presente estudo foi avaliar a resistência à fratura de coroas provisórias implanto ­ suportadas unitárias imediatas anteriores confeccionadas com facetas de resina acrílica e resina composta após diferentes tratamentos superficiais. Para isto 64 coroas provisórias implanto-suportadas foram confeccionadas e divididas 8 grupos experimentais (n=8), de acordo com o material de confecção, resina acrílica(RA) no grupo 1 ou resina composta(RC) nos grupos 2 a 8, e, tratamentos superficiais realizados na faceta: 1- sem tratamento, 2- sem tratamento, 3- metilmetacrilato(MM), 4- primer para metal(PM), 5- sistema adesivo(SA), 6-jateamento com óxido de alumínio(Al3O2)+MM, 7- Al3O2+PM e 8- Al3O2+SA . Os espécimes foram submetidos a 1x104 ciclos térmicos variando entre duas temperaturas (5ºC e 55 ºC) e posteriormente ao ensaio de resistência à fratura, com carga aplicada com velocidade de 0,5 mm/ min até a ocorrência de falha. Quando os valores de carga máxima para fratura foram analisados, o grupo 1 (controle) obteve os maiores valores (332 N média e ± 67 desvio padrão). Comparados ao controle, os grupos 2, 3, 4, 6 e 7 se mostraram estatisticamente diferentes (P < 0.05), com valores de carga máxima para fratura inferiores ao controle. Por outro lado os grupos 5 e 8 foram semelhantes e não demonstraram diferença estatística quando comparados com o controle (P > 0.05). A partir da análise dos dados, de acordo com a metodologia utilizada, pode-se concluir que o tratamento com sistema adesivo é uma boa opção para uso clínico, aumentando a resistência das coroas provisórias implanto-suportadas confeccionadas com resina acrílica e resina composta


The purpose of this study was to evaluate the fracture resistance of the immediate implant-supported provisional crown prepared with denture tooth and composite resin, after different surface treatments. Sixty-four screw-retained implant-supported provisional crown were divided into 8 groups (n= 8) according to the crown material, acrylic resin(AR) group1 or composite resin(CR) groups 2 to 8 and surface treatment performed: 1- no surface treatment, and 2- no surface treatment, 3- methyl methacrylate(MM), 4- metal primer(MP), 5- bonding system(BS) 6- alumina air abrasion (Al3O2) +MM, 7- Al3O2+MP and 8- Al3O2+BS. Specimens were subjected to 1x104 thermal cycles at two temperatures (5ºC and 55 ºC) and after that was performed the static mechanical test with a crosshead speed of 0.5 mm/ min until the sample fracture. When the maximum load to failure was analyzed the group 1 (control) had the highest values (332 N ± 67 mean and standard deviation). Compared to the control, groups 2, 3, 4, 6 and 7 were statistically different (P <0.05), with lower values of maximum than the control. Moreover the 5 and 8 groups were similar and showed no statistical difference when compared with the control (p>0.05). From the analysis of the data in accordance with the methodology used, it can be concluded that the treatment with bonding system is a good option for clinical use, increasing the resistance of implant-supported provisional crowns made with acrylic resin and composite resin


Subject(s)
Crowns , Flexural Strength , Compressive Strength , Acrylic Resins , Composite Resins , Materials Science , In Vitro Techniques , Statistics, Nonparametric
20.
Araraquara; s.n; 2014. 109 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-867825

ABSTRACT

Este estudo caracterizou mecanicamente uma porcelana feldspática de aplicação convencional e uma porcelana feldspática prensada, indicadas para infraestrutura em zircônia, quanto a resistência à flexão biaxial, dureza Vickers e tenacidade à fratura. Além disso, foi investigado o efeito da taxa de resfriamento após o ciclo de sinterização do glaze da porcelana na resistência à flexão biaxial de bicamadas zircônia/porcelana. Espécimes monocamada de VM9 (n=15) e Vita PM9 (n=15) (12,0 mm de diâmetro x 1.2 mm de espessura) foram confeccionados conforme as recomendações do fabricante e submetidos ao ensaio de resistência à flexão biaxial (MPa). Um fragmento de cada espécime fraturado foi aleatoriamente selecionado para a mensuração da dureza Vickers (n=15) (VHN). A tenacidade à fratura aparente(MPa.m½) foi determinada pela técnica da indentação Vickers (n=15). Para o ensaio de flexão biaxial dos bicamadas, discos de zircônia (Vita In-Ceram YZ) foram recobertos com porcelana convencional Vita VM9 (n=30) ou com porcelana prensada Vita PM9 (n=30). Após a simulação da queima de glaze, os espécimes foram submetidos a resfriamento rápido (n=15) ou lento (n=15). Após o ensaio de resistência à flexão, os espécimes foram analisados quanto ao tipo de fratura. Teste de T-Student para espécimes monocamada mostrou que Vita PM9 apresentou valores significantemente maiores de resistência à flexão biaxial (p<0,01) e dureza (p=0,017) em relação a Vita VM9, mas não quanto a tenacidade à fratura (p= 0.41). ANOVA a dois fatores (porcelana e método de resfriamento), utilizada para análise dos bicamadas indicou significância apenas para porcelanas, com superioridade para a combinação Vita PM9/zircônia (p<0,01). Porcelanas prensadas parecem ser uma alternativa mais efetiva para recobrimento de zircônia em relação as convencionais.


This study characterized mechanically a conventional and a pressed feldspathic porcelain indicated for zirconia core in terms of biaxial flexural strength, fracture toughness, Vickers hardness. In addition it was investigated the effect of the glaze cooling rate on the biaxial flexural strength of the zirconia/porcelain bilayer. Specimens monolayers of Vita VM9 (n=15) and Vita PM9 (n=15) (12.0 mm diameter x 1.2 mm thickness) were prepared according to manufacturer's recommendations for the biaxial flexural strength test (MPa). Afterwards, one fragment of each broken specimen was randomly selected for Vickers hardness measurements (n=15) (VHN). Apparent fracture toughness (MPa.m½) was determined by Vickers hardness indentation technique (n=15). For the biaxial flexural strength of bilayers, zirconia discs (Vita InCeram YZ) were veneered with the conventional porcelain Vita VM9 (n=30) or with the pressed porcelain Vita PM9 (n=30). After the glaze firing simulation, the specimens were submitted to fast (n=15) or slow cooling method (n=15). After the biaxial flexural test, the specimens were analyzed in relation to fracture pattern. T-Student tests were performed for the monolayer specimens, while two-way ANOVA (porcelain and cooling method) was used for the bilayer ones (α=.05). Vita PM9 exhibited significantly higher biaxial flexural strength (p<0.01) and hardness than VM9 (p=0.017). However, there was no significant difference (p= 0.41) in fracture toughness between the porcelains. The two-way ANOVA indicated significance only for the porcelain, with superiority for the combination Vita PM9/zirconia (p<0.01).The pressed porcelain seems to be a mechanically more effective alternative for zirconia veneering than the conventional one


Subject(s)
Analysis of Variance , Hardness , Dental Porcelain , Materials Science , Zirconium
SELECTION OF CITATIONS
SEARCH DETAIL